Find:
Searching for modeling large deformation w/2 soft tissues experimental results and analysis.
Restrict to:   Header   Title   Order by:   Expected citations   Hubs   Usage   Date   Try:   Google (CiteSeer)   Google (Web)   Yahoo!   MSN   CSB   DBLP
No documents match Boolean query. Trying non-Boolean relevance query.
500 documents found. Only retrieving 250 documents (System busy - maximum reduced). Order: relevance to query.

A Single Image Registration Method for CT Guided Interventions - Susil, Anderson, Taylor (1999)   (Correct)
for intracranial lesions [3] However, these methods largely involve the fixation of a stereotactic frame to
information with percutaneous therapy delivery to soft tissues. Extensive past efforts have been made to
with percutaneous therapy delivery to soft tissues. Extensive past efforts have been made to use CT

www.cs.jhu.edu/~rht/Papers/Miccai99/SusilPaper.pdf

Clare M. C. Tempany, MD - Elizabeth Stewart Md (2003)   (Correct)
ultrasound thermal therapy in experimental animal models: correlation of ablation volumes with pathology
of less than 20 weeks, and no dominant leiomyoma larger than 10 cm in diameter. All had symptomatic
ablation. The ultrasound beam penetrates through soft tissues and can be focused to target sites causing

splweb.bwh.harvard.edu:8000/pages/papers/pubs/../tempany/FUS-radiology2003.pdf

Frameworks for Evaluating Accuracy in CAOS - Simon Ph Center (1997)   (Correct)
can influence the accuracy of the resulting shape model, and therefore the resulting registration
action (e.g.robot positioning errors)Given the large number of potential error sources in CAOS
shape extraction or fiducial localization deformations of the anatomy induced by the fixturing

www.ri.cmu.edu/pub_files/pub1/simon_david_1997_4/simon_david_1997_4.pdf

Two- And Three-Dimensional Audio-Visual Speech Synthesis - Brooke, Scott (1998)   (Correct)   (5 citations)
parameter values for, or 'train'hidden Markov models (or HMMs) that capture both the sounds and facial
relatively modest gain can, however, represent a large improvement in word recognition rates,
described in Section 7, has been tested with deformation of the underlying wireframe head model. For

hunter.nsw.cmis.csiro.au/avsp98/papers/0006.ps

Two-Stage Neural Network For Volume Segmentation of Medical.. - Ahmed, Farag   (Correct)
or asynchronous mode. The architecture of ANNs is modeled after the human nervous system with some unique
spanned by the eigenvectors belonging to the largest eigenvalues. By doing so we ensure that the
which are known to yield good contrast between soft tissues, and for CT images if the analysis is

www.cvip.uofl.edu/Papers/pattern_letter_journal1.ps.gz

Intracranial Boundary Detection and Radio Frequency Correction.. - Mackiewich (1995)   (Correct)   (2 citations)
anisotropic diffusion. It then uses active contour models to find the brain's edge. The radio frequency
magnetic moment. When a human body is placed in a large magnetic field, many of the free hydrogen nuclei
of tumors, lesions, and other abnormalities in soft tissues, such as the brain. Several techniques for

fas.sfu.ca/pub/cs/theses/1995/BlairMackiewichMSc.ps.gz

Analysis and prediction of the brain deformation during a.. - Olivier Clatz Dea   (Correct)
internship was to develop a realistic biomechanical model of the brain to predict intra operative
ftp-sop.inria.fr/epidaure/Publications/Clatz/rapport.pdf

An Immersive Virtual Environment for DT-MRI Volume .. - Zhang, Demiralp.. (2001)   (Correct)   (1 citation)
better interpret the large and complex geometric models, and facilitates communication among a group of
our system helps the user better interpret the large and complex geometric models, and facilitates
to measure fiber-tract trajectories in fibrous soft tissues such as nerves, muscles, ligaments, and

www.cs.brown.edu/people/dfk/papers/viz01_brain.pdf

Frameless registration of MR and CT 3D volumetric data.. - Kumar, Dana, Anandan.. (1994)   (Correct)   (2 citations)
in this context. The geometric transformation model we initially assume is a global rigid or $D
solving for 6 or 12 unknown parameters over the large medical data sets. Instead we use an iterative
extended this approach to handle non-rigid deformations. They are able to use their technique to match

vis-ftp.cs.umass.edu/Papers/kumar/wacv94.ps.gz

Mechanical Design and Control of a HighBandwidth Shape.. - Parris Wellman William (1997)   (Correct)   (5 citations)
surgeons located simulated tumors in soft rubber models. They found that maximum finger speeds for 90
display must have small pin-to-pin spacing, produce large forces, have high pin stiffness and extremely
the finger tip. Our goal is to recreate skin deformations that might be produced by object features such

www.hrl.harvard.edu/people/students/parris/papers/iser1997/iser1997.PDF

Tactile After-Images from Static Contact - Singh, Fearing   (Correct)
to transient indentation have been studied and modelled. For tactile display system design, it is also
quantifying tactile "after-images" resulting from large loads applied over several seconds to the finger
describe the response of the human finger pad to deformation. Serina, Mote and Rempel [19] studied finger

robotics.eecs.berkeley.edu/~ronf/haptics98ujj.ps

Hexagonal Wavelet Processing of Digital Mammography - Laine, Schuler (1993)   (Correct)
is seen in the extralobular ductules. Mathematical models of phantoms were constructed to validate our
analyzed in the context of previously classified large horizontal features. Our strategy provides a
example, differences in attenuation of the various soft tissue structures in the female breast are small,

www.cis.ufl.edu/~ss4/papers/SPIE_Paper93/cpaper.ps.gz

Objective Measurement of Motion in the Orbit - Abràmoff   (Correct)
be studied in humans with non-invasive, imaging, modeling and invasive methods. The advantages o f the
orbit, since an invasive procedure carried a too large risk of inducing more scar tissue and increasing
the extraocular muscles [64]The motion and deformation of the orbital fat and the optic nerve are

www.isi.uu.nl/people/michael/downloads/thesis.72dpi.pdf

What is "Registration" and Why is it so Important in CAOS? - Simon Ph Center (1997)   (Correct)
However, this approach is prone to relatively large errors due to the difficulty of manually
loss and additional time required to suture the soft tissues in the vicinity of the markers. Several
and additional time required to suture the soft tissues in the vicinity of the markers. Several groups

www.ri.cmu.edu/pub_files/pub1/simon_david_1997_1/simon_david_1997_1.pdf

Volume segmentation of CT/MRI Images Using Multiscale.. - Ahmed, Farag (1997)   (Correct)
or asynchronous mode. The architecture of ANN is modeled after the human nervous system with some unique
spanned by the eigenvectors belonging to the largest eigenvalues. By doing that we ensure that the
which are known to yield good contrast between soft tissues, and for CT images if the analysis is

www.cvip.uofl.edu/Papers/icnn.ps.gz

Simulating 2D Tearing Phenomena for Interactive Medical.. - De Casson, Laugier (2000)   (Correct)
simulations require not only accurate geometric models of anatomical structures, but also realistic
through small incisions rather than by making a large incision exposing the organs operated on, will
temperature weakens the materials)the speed of deformation and the history of the deformation. The

ftp.inrialpes.fr/pub/sharp/publications/boux:laugier:computeranimation:00.ps.gz

Simulation of Tissue Cutting and Bleeding for.. - Basdogan, Chih-Hao.. (1999)   (Correct)   (9 citations)
of an incision through tissue surface is modeled in three steps: first, the collisions between
the auxiliary surface approach. We generated a large rectangular polyhedral surface, colored red, to
in consideration (e.g. cutting, bleeding, deformation, etc.by one so that it can be solved

touchlab.mit.edu/people/cagatay/mmvr99.ps

Fast Penetration Depth Estimation for Elastic Bodies - Using Deformed Distance   (Correct)
objects. We assume the continuum of non-rigid models are discretized using standard techniques, such
for in the following equation, selecting the largest possible solution to the quadratic equation: D
the computational challenges in modeling complex deformation among colliding bodies. But, many real-world

www.cs.unc.edu/~geom/DDF/iros01.pdf

A Display System for Surgical Navigation in ORL Surgery - Greimel, Backfrieder (2000)   (Correct)
is that they do not simulate the distorted optical model of a real endoscope. 3. System description As
the volume data into a mesh of polygons. Due to the large amount of voxels to be processed and the
good contrast for bones, MR images show especially soft tissues, SPECT and PET are used for functional

www.cg.tuwien.ac.at/studentwork/CESCG-2000/WGreimel/paper.ps.gz

First 20 documents  Next 20

Try your query at:   Google (CiteSeer)   Google (Web)   Yahoo!   MSN   CSB   DBLP

CiteSeer.IST - Copyright Penn State and NEC