A Single Image Registration Method for CT Guided Interventions - Susil, Anderson, Taylor (1999)(Correct)
for intracranial lesions [3] However, these methods largely involve the fixation of a stereotactic frame to
information with percutaneous therapy delivery to softtissues. Extensive past efforts have been made to
with percutaneous therapy delivery to softtissues. Extensive past efforts have been made to use CT www.cs.jhu.edu/~rht/Papers/Miccai99/SusilPaper.pdf
Clare M. C. Tempany, MD - Elizabeth Stewart Md (2003)(Correct)
ultrasound thermal therapy in experimental animal models: correlation of ablation volumes with pathology
of less than 20 weeks, and no dominant leiomyoma larger than 10 cm in diameter. All had symptomatic
ablation. The ultrasound beam penetrates through softtissues and can be focused to target sites causing splweb.bwh.harvard.edu:8000/pages/papers/pubs/../tempany/FUS-radiology2003.pdf
Frameworks for Evaluating Accuracy in CAOS - Simon Ph Center (1997)(Correct)
can influence the accuracy of the resulting shape model, and therefore the resulting registration
action (e.g.robot positioning errors)Given the large number of potential error sources in CAOS
shape extraction or fiducial localization deformations of the anatomy induced by the fixturing www.ri.cmu.edu/pub_files/pub1/simon_david_1997_4/simon_david_1997_4.pdf
Two- And Three-Dimensional Audio-Visual Speech Synthesis - Brooke, Scott (1998)(Correct)(5 citations)
parameter values for, or 'train'hidden Markov models (or HMMs) that capture both the sounds and facial
relatively modest gain can, however, represent a large improvement in word recognition rates,
described in Section 7, has been tested with deformation of the underlying wireframe head model. For hunter.nsw.cmis.csiro.au/avsp98/papers/0006.ps
Two-Stage Neural Network For Volume Segmentation of Medical.. - Ahmed, Farag(Correct)
or asynchronous mode. The architecture of ANNs is modeled after the human nervous system with some unique
spanned by the eigenvectors belonging to the largest eigenvalues. By doing so we ensure that the
which are known to yield good contrast between softtissues, and for CT images if the analysis is www.cvip.uofl.edu/Papers/pattern_letter_journal1.ps.gz
Intracranial Boundary Detection and Radio Frequency Correction.. - Mackiewich (1995)(Correct)(2 citations)
anisotropic diffusion. It then uses active contour models to find the brain's edge. The radio frequency
magnetic moment. When a human body is placed in a large magnetic field, many of the free hydrogen nuclei
of tumors, lesions, and other abnormalities in softtissues, such as the brain. Several techniques for fas.sfu.ca/pub/cs/theses/1995/BlairMackiewichMSc.ps.gz
An Immersive Virtual Environment for DT-MRI Volume .. - Zhang, Demiralp.. (2001)(Correct)(1 citation)
better interpret the large and complex geometric models, and facilitates communication among a group of
our system helps the user better interpret the large and complex geometric models, and facilitates
to measure fiber-tract trajectories in fibrous softtissues such as nerves, muscles, ligaments, and www.cs.brown.edu/people/dfk/papers/viz01_brain.pdf
Frameless registration of MR and CT 3D volumetric data.. - Kumar, Dana, Anandan.. (1994)(Correct)(2 citations)
in this context. The geometric transformation model we initially assume is a global rigid or $D
solving for 6 or 12 unknown parameters over the large medical data sets. Instead we use an iterative
extended this approach to handle non-rigid deformations. They are able to use their technique to match vis-ftp.cs.umass.edu/Papers/kumar/wacv94.ps.gz
Mechanical Design and Control of a HighBandwidth Shape.. - Parris Wellman William (1997)(Correct)(5 citations)
surgeons located simulated tumors in soft rubber models. They found that maximum finger speeds for 90
display must have small pin-to-pin spacing, produce large forces, have high pin stiffness and extremely
the finger tip. Our goal is to recreate skin deformations that might be produced by object features such www.hrl.harvard.edu/people/students/parris/papers/iser1997/iser1997.PDF
Tactile After-Images from Static Contact - Singh, Fearing(Correct)
to transient indentation have been studied and modelled. For tactile display system design, it is also
quantifying tactile "after-images" resulting from large loads applied over several seconds to the finger
describe the response of the human finger pad to deformation. Serina, Mote and Rempel [19] studied finger robotics.eecs.berkeley.edu/~ronf/haptics98ujj.ps
Hexagonal Wavelet Processing of Digital Mammography - Laine, Schuler (1993)(Correct)
is seen in the extralobular ductules. Mathematical models of phantoms were constructed to validate our
analyzed in the context of previously classified large horizontal features. Our strategy provides a
example, differences in attenuation of the various softtissue structures in the female breast are small, www.cis.ufl.edu/~ss4/papers/SPIE_Paper93/cpaper.ps.gz
Objective Measurement of Motion in the Orbit - Abràmoff(Correct)
be studied in humans with non-invasive, imaging, modeling and invasive methods. The advantages o f the
orbit, since an invasive procedure carried a too large risk of inducing more scar tissue and increasing
the extraocular muscles [64]The motion and deformation of the orbital fat and the optic nerve are www.isi.uu.nl/people/michael/downloads/thesis.72dpi.pdf
What is "Registration" and Why is it so Important in CAOS? - Simon Ph Center (1997)(Correct)
However, this approach is prone to relatively large errors due to the difficulty of manually
loss and additional time required to suture the softtissues in the vicinity of the markers. Several
and additional time required to suture the softtissues in the vicinity of the markers. Several groups www.ri.cmu.edu/pub_files/pub1/simon_david_1997_1/simon_david_1997_1.pdf
Volume segmentation of CT/MRI Images Using Multiscale.. - Ahmed, Farag (1997)(Correct)
or asynchronous mode. The architecture of ANN is modeled after the human nervous system with some unique
spanned by the eigenvectors belonging to the largest eigenvalues. By doing that we ensure that the
which are known to yield good contrast between softtissues, and for CT images if the analysis is www.cvip.uofl.edu/Papers/icnn.ps.gz
Simulating 2D Tearing Phenomena for Interactive Medical.. - De Casson, Laugier (2000)(Correct)
simulations require not only accurate geometric models of anatomical structures, but also realistic
through small incisions rather than by making a large incision exposing the organs operated on, will
temperature weakens the materials)the speed of deformation and the history of the deformation. The ftp.inrialpes.fr/pub/sharp/publications/boux:laugier:computeranimation:00.ps.gz
Simulation of Tissue Cutting and Bleeding for.. - Basdogan, Chih-Hao.. (1999)(Correct)(9 citations)
of an incision through tissue surface is modeled in three steps: first, the collisions between
the auxiliary surface approach. We generated a large rectangular polyhedral surface, colored red, to
in consideration (e.g. cutting, bleeding, deformation, etc.by one so that it can be solved touchlab.mit.edu/people/cagatay/mmvr99.ps
Fast Penetration Depth Estimation for Elastic Bodies - Using Deformed Distance(Correct)
objects. We assume the continuum of non-rigid models are discretized using standard techniques, such
for in the following equation, selecting the largest possible solution to the quadratic equation: D
the computational challenges in modeling complex deformation among colliding bodies. But, many real-world www.cs.unc.edu/~geom/DDF/iros01.pdf
A Display System for Surgical Navigation in ORL Surgery - Greimel, Backfrieder (2000)(Correct)
is that they do not simulate the distorted optical model of a real endoscope. 3. System description As
the volume data into a mesh of polygons. Due to the large amount of voxels to be processed and the
good contrast for bones, MR images show especially softtissues, SPECT and PET are used for functional www.cg.tuwien.ac.at/studentwork/CESCG-2000/WGreimel/paper.ps.gz